Solution: Aluminium - Jesper Stærmose, Odder, Denmark
Name and country location of installation: Jesper Stærmose, Odder, Demark
Industry: Aluminium
Application or process: Extraction of fume from plasma cutting og 2 mm aluminium sheets. Operating approx. 10 minutes cutting per sheet alternating with down time cleaning 2-5 minutes. (fan off)
Date of Installation: 1999
Filter type and size: FMC200-6
Airflow volume: 3,500 m3/h
Filter material: CA190-40F
Fan type and other major components: FM625 fan with noise box |
|
|
|